Real estate

warning: this is not how to include the shop layout in a page, please read docs

Preview

Filtering by Clear filters
TCS Keep-Alive® (KA) devices are used to supply power to decoders during times of power interruption due to dirty track or problematic track work. This Keep-Alive® includes a 2-Pin Quick Connector Harness for plugging into decoders with a compatible socket. SKU: 2005
$25.56
TCS Keep-Alive® (KA) devices are used to supply power to decoders during times of power interruption due to dirty track or problematic track work.   Newly-redesigned and coming in at half the size of a KA4, the KA2 will power HO or N scale locomotives with approximately one-third of the capacitance of KA3/KA4 devices (depending on the locomotive and motor).   SKU:  2004
$25.56
TCS Keep-Alive® (KA) devices are used to supply power to decoders during times of power interruption due to dirty track or problematic track work.   Newly-redesigned and coming in at half the size of a KA4, the KA2 will power HO or N scale locomotives with approximately one-third of the capacitance of KA3/KA4 devices (depending on the locomotive and motor).   This Keep-Alive® includes a 2-Pin Quick Connector Harness for plugging into decoders with a compatible socket. SKU:  2003
$25.56
TCS Keep-Alive® (KA) devices are used to supply power to decoders during times of power interruption due to dirty track or problematic track work.   Newly-redesigned and coming in at half the size of a KA3, the KA1 will power HO or N scale locomotives with approximately one-third of the capacitance of KA3/KA4 devices (depending on the locomotive and motor).   This Keep-Alive® includes a 2-Pin Quick Connector Harness for plugging into decoders with a compatible socket. SKU:  2002
$25.56
TCS Keep-Alive® (KA) devices are used to supply power to decoders during times of power interruption due to dirty track or problematic track work. The KA-N1 can power an N-scale locomotive for 1-2 seconds over dirty track and power interruptions (depending on the number of lights and efficiency of the motor).   This Keep Alive® has been specifically designed to be as physically small as possible. This product uses a slightly lower voltage and has a lower capacity compared to our larger Keep Alive products such as the KA1, KA4, etc., and is intended to be used with N-scale decoders, such as the K7D4 and more! SKU:  2010
$15.96
Installation instructions https://www.markschutzer.com/DCC_Articles/PDF/ChargerBoardinstallation.pdf  
$15.00
  • 8 CV-Selectable Steam & Diesel Sound Schemes Included
  • Mobile Decoder with SoundFX v3
  • Fits many HO locomotives
  • Digitrax Easy Connect 8 Pin Harness
  • Motor 1.0 Amp/2 Amps Peak
  • 4 FX3 Functions, 200ma Output
  • New sound .spjs loadable with Digitrax USB programmer
  • 8 Ohm 10 mm x 18 mm Oval Speaker
  • 100uF Capacitor
$63.20
  • 8 CV-Selectable Steam & Diesel Sound Schemes Included
  • Mobile Decoder with SoundFX v3
  • Fits many HO locomotives
  • 21MTC interface
  • Motor 1.0 Amp/2 Amps Peak
  • 8 FX3 Functions, 200ma Output
  • New sound .spjs loadable with Digitrax USB programmer
$52.00

The LokPilot 5 DCC is the "twin brother" of the LokPilot 5. The two share almost all characteristics, however, the LokPilot 5 DCC is a pure DCC decoder and cannot be used on analog AC systems. This lack of flexibility comes with a cheaper price.

LokPilot 5 decoders are offered with all common interfaces.

Modes

The LokPilot 5 DCC is a "pure-bred" DCC decoder. 14 to 128 speed steps are as natural as 2- and 4-digit addresses. Up to 32 functions can be triggered. Thanks to RailComPlus® the decoders register automatically with a suitable DCC system like the ESU CabControl.

The decoder accepts all DCC programming modes and thanks to RailCom® the CV values ​​can be read on the main track with RailCom equipped DCC systems. For command stations that only program the CVs from 1-255 auxiliary CV registers exist.

The LokPilot 5 DCC decoder recognizes the Märklin® braking sections as well as the ZIMO® HLU / ZACKCommands or the Lenz® ABC system. Also braking with DCC brake modules or with DC voltageis possible. It also stops with a Selectrix® brake diode. An ABC automatic shuttle trainenables automatic commuting between two train stations.

The LokPilot 5 DCC decoder can be used on analog DC trains. The top speedcan be set separately.

The decoder switches between the operating modes fully automatically "on-the-fly".

Features

We know that you want your locomotives to be as realistic as possible. Therefore we have the LokPilot 5DCC packed with function outputs. Depending on the interface version, each LokPilot offers 5 DCCDecoder at least 10 amplified function outputs with 250mA output current each. In the executionswith PluX22 or 21MTC interface there are 4 outputs to control servos orLogic level outputs added. All-important lighting functions are available. The brightness of each outputcan be set separately. The decoder masters automatic pushing and pullingwhen uncoupling for ROCO®, Krois® and Telex® couplings.

Motor control

The engine control of the LokPilot 5 DCC has been fundamentally improved again. A variably adjustablePWM clock frequency from 10kHz to 50kHz ensures super quiet operation, especially with bell-armature motors.Operation - The typical “hum” is a thing of the past. The load control now has up to10 CVs  which can be adjusted for difficult cases. The unique "Autotune" function enablesthe automatic calibration of the decoder to the motor. The LokPilot 5 DCC decoder delivers up to 1.5A of motor current. Enough juice even for older motors.

SKU:  59629
$29.52



How to install

You can now add layouts you create in the Shop Admin into any post or page. To make it simple a Shortcode Generator is included. You can access it via this button.

The first button is the shortcode genreator launcher and the second one ( the one with a plus ) ads a single audio player to the page from the media gallery.